Sign In | Join Free | My disqueenfrance.com
China China World Technology Medical Equipment Service Group logo
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
Verified Supplier

5 Years

Home > Used Ultrasound Transducer >

Toshiba PVM-375AT Convex Array Transducer Ultrasound Probe 3.0MHz. - 6.0MHz

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Toshiba PVM-375AT Convex Array Transducer Ultrasound Probe 3.0MHz. - 6.0MHz

Brand Name : Toshiba

Model Number : PVM-375AT

MOQ : 1pcs

Payment Terms : T/T(wire transfer), Western Union, Paypal

Packaging Details : Carton

Product Name : Toshiba PVM-375AT Convex Array Transducer Ultrasound Probe 3.0 MHz. - 6.0 MHz

Brand : Toshiba

Part No : PVM-375AT

Form Factor : Curved Array

Applications : Abdominal, Obstetrics, Gynaecology

Frequency Range : 3.0 - 6.0 MHz.

Compatibility : Toshiba PowerVision 6000 (SSA-370A); Toshiba Nemio 17 (SSA-550A)

Condition : Used

Warranty : 90 days

MOQ : One piece

Contact Now

Toshiba PVM-375AT Convex Array Transducer Ultrasound Probe 3.0 MHz. - 6.0 MHz

The Toshiba PVM-375AT Curved Array transducer has a frequency range of 3.0 MHz. - 6.0 MHz

Form Factor Curved Array
Applications Abdominal, Obstetrics, Gynaecology
Frequency Range 3.0 - 6.0 MHz.
Compatibility Toshiba PowerVision 6000 (SSA-370A); Toshiba Nemio 17 (SSA-550A)

Toshiba PVM-375AT Convex Array Transducer Ultrasound Probe 3.0MHz. - 6.0MHz

Cleaning and Disinfection

Clean and disinfect (or sterilize) the probe as needed after each test. Always sterilize the needle guiding stent after performing the biopsy procedure. Otherwise, the probe and needle guide holder can become a source of infection. Please note the cleaning instructions.

1. To prevent infection, wear sterile gloves when cleaning and disinfecting the probe.

2. After disinfection, rinse the probe thoroughly with sterile water to remove chemical residue. Chemical residues on the probe can be harmful to humans.

3. If the probe is not cleaned and sterilized, the probe may become a source of infection.

NOTE: Gently wipe off the ultrasound gel after the exam. Otherwise, the ultrasound gel may solidify and affect the image quality of the transducer.

NOTE: Do not overheat the probe (above 55°C) during cleaning and disinfection. High temperatures can deform or damage the probe.

cleaning

Refer to the manual for instructions and follow hospital policies and cleaning procedures.

1. Remove the probe from the system.

2. Wear sterile gloves to prevent infection.

3. Clean the transmitter with clean or soapy water to remove debris, or wipe the transmitter with a soft urethane sponge. Avoid using brushes as they can damage the transducer.

4. After rinsing, dry the transducer with a sterile towel or gauze. Do not heat the transmitter to dry it.

Disinfect with a spray or wipe

1. Wear sterile gloves to prevent infection.

2. Spray or wipe the transmitter with disinfectant after cleaning. Follow the exposure times and methods recommended by the disinfectant manufacturer.

3. Remove any residue from the transducer with a soft cloth dampened with water.

4. After cleaning, wipe the water off the transducer with a sterile cloth or gauze.

Disinfection by immersion

1. Wear sterile gloves to prevent infection.

2. Clean the transducers before disinfecting. Mindray recommends the following solutions for transducer sterilization: Consult the chemical manufacturer's manual for disinfectant concentration, disinfectant dilution, and precautions for use. Do not immerse the transducer connector or adjacent cables in water or solution. Immerse the transmitter in the disinfectant solution for the short time recommended by the manufacturer.

(For example, for Cidex OPA, the manufacturer recommends a soak time of at least 12 minutes). Follow local regulations when selecting and using disinfectants.

warm!

The minimum distance between the cable connection and the water level is 10 mm.

3. Flush the transmitter with a large volume of sterile water (approximately 2 gallons) for at least 1 minute to remove any chemical residue. Alternatively, you can rinse the transmitter using the rinsing method recommended by the disinfectant manufacturer.

4. After cleaning, wipe the water off the transducer with a sterile cloth or gauze. Do not heat the transmitter to dry it.

If you're interested in Toshiba PVM-375AT Convex Array Transducer Ultrasound Probe 3.0 MHz. - 6.0 MHz ,feel free to contact us .Thank you .


Product Tags:

Toshiba PVM-375AT Convex Array Transducer

      

6.0MHz Convex Array Transducer

      
China Toshiba PVM-375AT Convex Array Transducer Ultrasound Probe 3.0MHz. - 6.0MHz wholesale

Toshiba PVM-375AT Convex Array Transducer Ultrasound Probe 3.0MHz. - 6.0MHz Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0